English
Language : 

K60P100M100SF2RM Datasheet, PDF (961/1809 Pages) Freescale Semiconductor, Inc – K60 Sub-Family Reference Manual
Field
9
COMP1
8
COMBINE1
7
Reserved
6
FAULTEN0
5
SYNCEN0
4
DTEN0
3
DECAP0
Chapter 39 FlexTimer (FTM)
FTMx_COMBINE field descriptions (continued)
Description
0 The dual edge capture mode in this pair of channels is disabled.
1 The dual edge capture mode in this pair of channels is enabled.
Complement of Channel (n) for n = 2
Enables complementary mode for the combined channels. In complementary mode the channel (n+1)
output is the inverse of the channel (n) output.
This field is write protected. It can be written only when MODE[WPDIS] = 1.
0 The channel (n+1) output is the same as the channel (n) output.
1 The channel (n+1) output is the complement of the channel (n) output.
Combine Channels for n = 2
Enables the combine feature for channels (n) and (n+1).
This field is write protected. It can be written only when MODE[WPDIS] = 1.
0 Channels (n) and (n+1) are independent.
1 Channels (n) and (n+1) are combined.
This read-only field is reserved and always has the value zero.
Fault Control Enable for n = 0
Enables the fault control in channels (n) and (n+1).
This field is write protected. It can be written only when MODE[WPDIS] = 1.
0 The fault control in this pair of channels is disabled.
1 The fault control in this pair of channels is enabled.
Synchronization Enable for n = 0
Enables PWM synchronization of registers C(n)V and C(n+1)V.
0 The PWM synchronization in this pair of channels is disabled.
1 The PWM synchronization in this pair of channels is enabled.
Deadtime Enable for n = 0
Enables the deadtime insertion in the channels (n) and (n+1).
This field is write protected. It can be written only when MODE[WPDIS] = 1.
0 The deadtime insertion in this pair of channels is disabled.
1 The deadtime insertion in this pair of channels is enabled.
Dual Edge Capture Mode Captures for n = 0
Enables the capture of the FTM counter value according to the channel (n) input event and the
configuration of the dual edge capture bits.
This field applies only when FTMEN = 1 and DECAPEN = 1.
DECAP bit is cleared automatically by hardware if dual edge capture – one-shot mode is selected and
when the capture of channel (n+1) event is made.
0 The dual edge captures are inactive.
1 The dual edge captures are active.
Table continues on the next page...
K60 Sub-Family Reference Manual, Rev. 6, Nov 2011
Freescale Semiconductor, Inc.
961