Communication interfaces
3.9.2.3 USB power management
The regulator should be put into STANDBY mode whenever the chip is in Stop mode.
This can be done by setting the SIM_SOPT1[USBSTBY] bit.
3.9.2.4 USB controller configuration
This section summarizes how the module has been configured in the chip. For a
comprehensive description of the module itself, see the module’s dedicated chapter.
Peripheral
bridge 0
Register
access
Transfers
USB controller
Module signals
Topic
Full description
System memory map
Clocking
Transfers
Signal Multiplexing
Figure 3-56. USB controller configuration
Table 3-63. Reference links to related information
Related module
USB controller
Crossbar switch
Port control
Reference
USB controller
System memory map
Clock Distribution
Crossbar switch
Signal Multiplexing
NOTE
When USB is not used in the application, it is recommended
that the USB regulator VREGIN and VOUT33 pins remain
floating.
3.9.2.5 USB DCD Configuration
This section summarizes how the module has been configured in the chip. For a
comprehensive description of the module itself, see the module’s dedicated chapter.