Field
18–16
DELVOL
15–8
SMOD
7–6
Reserved
Chapter 55 Touch sense input (TSI)
TSIx_SCANC field descriptions (continued)
Description
00001
00010
00011
00100
00101
00110
00111
01000
01001
01010
01011
01100
01101
01110
01111
10000
10001
10010
10011
10100
10101
10110
10111
11000
11001
11010
11011
11100
11101
11110
11111
2 µA charge current
3 µA charge current
4 µA charge current
5 µA charge current
6 µA charge current
7 µA charge current
8 µA charge current
9 µA charge current
10 µA charge current
11 µA charge current
12 µA charge current
13 µA charge current
14 µA charge current
15 µA charge current
16 µA charge current
17 µA charge current
18 µA charge current
19 µA charge current
20 µA charge current
21 µA charge current
22 µA charge current
23 µA charge current
24 µA charge current
25 µA charge current
26 µA charge current
27 µA charge current
28 µA charge current
29 µA charge current
30 µA charge current
31 µA charge current
32 µA charge current
Delta voltage select applied to analog oscillators
000 100 mV delta voltage is applied
001 150 mV delta voltage is applied
010 200 mV delta voltage is applied
011 250 mV delta voltage is applied
100 300 mV delta voltage is applied
101 400 mV delta voltage is applied
110 500 mV delta voltage is applied
111 600 mV delta voltage is applied
Scan modulo
00000000 Continuous scan
Others
Scan period modulo
This read-only field is reserved and always has the value zero.
Table continues on the next page...
K60 Sub-Family Reference Manual, Rev. 6, Nov 2011
Freescale Semiconductor, Inc.