English
Language : 

K60P100M100SF2RM Datasheet, PDF (1001/1809 Pages) Freescale Semiconductor, Inc – K60 Sub-Family Reference Manual
MOD = C(n+1)V
FTM counter
Chapter 39 FlexTimer (FTM)
C(n)V
CNTIN
channel (n) output
with ELSnB:ELSnA = 1:0
not fully 100% duty cycle
channel (n) output
with ELSnB:ELSnA = X:1
not fully 0% duty cycle
Figure 39-191. Channel (n) Output If (CNTIN < C(n)V < MOD) and (C(n)V is Almost Equal
to CNTIN) and (C(n+1)V = MOD)
MOD
FTM counter
C(n+1)V
C(n)V = CNTIN
channel (n) output
with ELSnB:ELSnA = 1:0
not fully 100% duty cycle
channel (n) output
with ELSnB:ELSnA = X:1
not fully 0% duty cycle
Figure 39-192. Channel (n) Output If (C(n)V = CNTIN) and (CNTIN < C(n+1)V < MOD) and
(C(n+1)V is Almost Equal to MOD)
K60 Sub-Family Reference Manual, Rev. 6, Nov 2011
Freescale Semiconductor, Inc.
1001