Section 23 Gigabit Ethernet Controller (GETHER)
23.3.50 CAM Entry Table POST1 Register (TSU_POST1)
When using the CAM, the conditions for referring to each CAM entry table can be specified by
using the TSU_POST1 to TSU_POST4 registers. TSU_POST1 specifies the conditions for
referring to TSU_ADRH0 to TSU_ADRH7 and TSU_ADRL0 to TSU_ADRL7. The settings of
this register are valid when the POSTENU bit in TSU_FWSLC is set to 1.
Bit: 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
POST0[3:0]
POST1[3:0]
POST2[3:0]
POST3[3:0]
Initial value: 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
R/W: R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Bit: 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
POST4[3:0]
POST5[3:0]
POST6[3:0]
POST7[3:0]
Initial value: 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
R/W: R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Bit
Bit Name
31 to 28 POST0[3:0]
27 to 24 POST1[3:0]
Initial
Value
All 0
All 0
R/W Description
R/W These bits set the conditions for referring to CAM entry
table 0. By setting multiple bits to 1, multiple conditions
can be selected.
POST0[3]: CAM entry table 0 is referred to in port 0
reception.
POST0[2]: CAM entry table 0 is referred to in port 0 to 1
relay.
POST0[1]: CAM entry table 0 is referred to in port 1
reception.
POST0[0]: CAM entry table 0 is referred to in port 1 to 0
relay.
R/W These bits set the conditions for referring to CAM entry
table 1. By setting multiple bits to 1, multiple conditions
can be selected.
POST1[3]: CAM entry table 1 is referred to in port 0
reception.
POST1[2]: CAM entry table 1 is referred to in port 0 to 1
relay.
POST1[1]: CAM entry table 1 is referred to in port 1
reception.
POST1[0]: CAM entry table 1 is referred to in port 1 to 0
relay.
Rev. 1.00 Oct. 01, 2007 Page 877 of 1956