English
Language : 

SH7763 Datasheet, PDF (1204/2026 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperHTM RISC Engine Family SH-4A Series
Section 28 Serial Communication Interface with FIFO/IrDA Interface (SCIF/IrDA)
Initial
Bit
Bit Name Value R/W Description
3
FER
0
R
Framing Error
In asynchronous mode, indicates whether or not a
framing error has been found in the data that is to be
read next from SCFRDR.
0: There is no framing error that is to be read from
SCFRDR
[Clearing conditions]
• Power-on reset or manual reset
• When there is no framing error in the data that is to
be read next from SCFRDR
1: There is a framing error that is to be read from
SCFRDR
[Setting condition]
• When there is a framing error in the data that is to
be read next from SCFRDR
2
PER
0
R
Parity Error
In asynchronous mode, indicates whether or not a
parity error has been found in the data that is to be read
next from SCFRDR.
0: There is no parity error that is to be read from
SCFRDR
[Clearing conditions]
• Power-on reset or manual reset
• When there is no parity error in the data that is to be
read next from SCFRDR
1: There is a parity error in the receive data that is to be
read from SCFRDR
[Setting condition]
• When there is a parity error in the data that is to be
read next from SCFRDR
Rev. 1.00 Oct. 01, 2007 Page 1138 of 1956
REJ09B0256-0100