English
Language : 

SH7763 Datasheet, PDF (1267/2026 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperHTM RISC Engine Family SH-4A Series
Section 29 Serial I/O with FIFO (SIOF)
29.3.6 Transmit Control Data Register (SITCR)
SITCR is a 32-bit readable/writable register that specifies transmit control data of the SIOF.
SITCR can be specified only when the FL bit in SIMDR is specified as 1xxx (x: don't care.).
SITCR is initialized by the conditions specified in table 29.3, Register State of SIOF in Each
Processing Mode, or by a transmit reset caused by the TXRST bit in SICTR.
BIt: 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
SITC0[15:0]
Initial value: — — — — — — — — — — — — — — — —
R/W: R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
BIt: 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
SITC1[15:0]
Initial value: — — — — — — — — — — — — — — — —
R/W: R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Initial
Bit
Bit Name Value R/W
31 to 16 SITC0[15:0] H'0000 R/W
15 to 0 SITC1[15:0] H'0000 R/W
Description
Control Channel 0 Transmit Data
Specify data to be output from the SIOF_TXD pin as
control channel 0 transmit data. The position of the
control channel 0 data in the transmit or receive frame
is specified by the CD0A bit in SICDAR.
• These bits are valid only when the CD0E bit in
SICDAR is set to 1.
Control Channel 1 Transmit Data
Specify data to be output from the SIOF_TXD pin as
control channel 1 transmit data. The position of the
control channel 1 data in the transmit or receive frame
is specified by the CD1A bit in SICDAR.
• These bits are valid only when the CD1E bit in
SICDAR is set to 1.
Rev. 1.00 Oct. 01, 2007 Page 1201 of 1956
REJ09B0256-0100