English
Language : 

SH7205 Datasheet, PDF (1583/1904 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7200 Series
Section 30 Power-Down Modes
Initial
Bit Bit Name Value R/W Description
6
MSTP66 1
R/W Module Stop 66
When set to 1, the clock supply to the SSIF1 is halted.
0: SSIF1 runs.
1: Clock supply to SSIF1 is halted.
5
MSTP65 1
R/W Module Stop 65
When set to 1, the clock supply to the SSIF2 is halted.
0: SSIF2 runs.
1: Clock supply to SSIF2 is halted.
4
MSTP64 1
R/W Module Stop 64
When set to 1, the clock supply to the SSIF3 is halted.
0: SSIF3 runs.
1: Clock supply to SSIF3 is halted.
3
MSTP63 1
R/W Module Stop 63
When set to 1, the clock supply to the SSIF4 is halted.
0: SSIF4 runs.
1: Clock supply to SSIF4 is halted.
2
MSTP62 1
R/W Module Stop 62
When set to 1, the clock supply to the SSIF5 is halted.
0: SSIF5 runs.
1: Clock supply to SSIF5 is halted.
1, 0 
All 1 R
Reserved
These bits are always read as 1. The write value should
always be 1.
Rev. 1.00 Mar. 25, 2008 Page 1551 of 1868
REJ09B0372-0100