Section 5 Exception Handling
The code corresponding to the each interrupt source is set in INTEVT. The BL, MD, and RB
bits are set to 1 in SR, and a branch is made to VBR + H'0600. When the INTMU bit in
CPUOPM is 1, IMASK bit in SR is changed to accepted interrupt level. For details, see section
13, Interrupt Controller (INTC).
Module_interruption()
{
SPC = PC;
SSR = SR;
SGR = R15;
INTEVT = H'0000 0400 ~ H'0000 3FE0;
SR.MD = 1;
SR.RB = 1;
SR.BL = 1;
if (cond) SR.IMASK = level_of accepted_interrupt ();
PC = VBR + H'0000 0600;
}
5.6.4 Priority Order with Multiple Exceptions
With some instructions, such as instructions that make two accesses to memory, and the
indivisible pair comprising a delayed branch instruction and delay slot instruction, multiple
exceptions occur. Care is required in these cases, as the exception priority order differs from the
normal order.
(1) Instructions that Make Two Accesses to M emory
With MAC instructions, memory-to-memory arithmetic/logic instructions, TAS instructions, and
MOVUA instructions, two data transfers are performed by a single instruction, and an exception
will be detected for each of these data transfers. In these cases, therefore, the following order is
used to determine priority.
1. Data address error in first data transfer
2. TLB miss in first data transfer
3. TLB protection violation in first data transfer
4. Initial page write exception in first data transfer
5. Data address error in second data transfer
6. TLB miss in second data transfer
Rev. 1.00 Nov. 22, 2007 Page 127 of 1692