English
Language : 

SH7263 Datasheet, PDF (670/1862 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7260 Series
Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
(12) Operation when Error Occurs during PWM Mode 1 Operation, and Operation is
Restarted in Reset-Synchronized PWM Mode
Figure 11.124 shows an explanatory diagram of the case where an error occurs in PWM mode 1
and operation is restarted in reset-synchronized PWM mode after re-setting.
MTU2 module output
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19
RESET TMDR TOER TIOR PFC TSTR Match Error PFC TSTR TMDR TIOR TIOR TOER TOCR TMDR TOER PFC TSTR
(PWM1) (1) (1 init (MTU2) (1)
occurs (PORT) (0) (normal) (0 init(disabled) (0)
(RPWM) (1) (MTU2) (1)
0 out)
0 out)
TIOC3A
TIOC3B
Not initialized (TIOC3B)
TIOC3D
Not initialized (TIOC3D)
Port output
PE8
PE9
High-Z
High-Z
PE11
High-Z
Figure 11.124 Error Occurrence in PWM Mode 1,
Recovery in Reset-Synchronized PWM Mode
1 to 14 are the same as in figure 11.123.
15. Select the reset-synchronized PWM output level and cyclic output enabling/disabling with
TOCR.
16. Set reset-synchronized PWM.
17. Enable channel 3 and 4 output with TOER.
18. Set MTU2 output with the PFC.
19. Operation is restarted by TSTR.
Rev. 2.00 Mar. 14, 2008 Page 636 of 1824
REJ09B0290-0200