English
Language : 

SH7263 Datasheet, PDF (661/1862 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7260 Series
Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
(3) Operation when Error Occurs during Normal Mode Operation, and Operation is
Restarted in PWM Mode 2
Figure 11.115 shows an explanatory diagram of the case where an error occurs in normal mode
and operation is restarted in PWM mode 2 after re-setting.
MTU2 module output
TIOC*A
1
2
3
RESET TMDR TOER
(normal) (1)
4
5
6
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
7
Match
8
9
10 11 12
Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (PWM2) (1 init
0 out)
13
PFC
(MTU2)
14
TSTR
(1)
Not initialized (cycle register)
TIOC*B
Port output
PEn
High-Z
PEn
High-Z
n = 0 to 15
Figure 11.115 Error Occurrence in Normal Mode, Recovery in PWM Mode 2
1 to 10 are the same as in figure 11.113.
11. Set PWM mode 2.
12. Initialize the pins with TIOR. (In PWM mode 2, the cycle register pins are not initialized. If
initialization is required, initialize in normal mode, then switch to PWM mode 2.)
13. Set MTU2 output with the PFC.
14. Operation is restarted by TSTR.
Note: PWM mode 2 can only be set for channels 0 to 2, and therefore TOER setting is not
necessary.
Rev. 2.00 Mar. 14, 2008 Page 627 of 1824
REJ09B0290-0200