English
Language : 

SH7263 Datasheet, PDF (668/1862 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7260 Series
Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
(10) Operation when Error Occurs during PWM Mode 1 Operation, and Operation is
Restarted in Phase Counting Mode
Figure 11.122 shows an explanatory diagram of the case where an error occurs in PWM mode 1
and operation is restarted in phase counting mode after re-setting.
1
2
3
RESET TMDR TOER
(PWM1) (1)
MTU2 module output
TIOC*A
4
5
6
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
7
8
9
10 11
Match Error PFC TSTR TMDR
occurs (PORT) (0) (PCM)
12 13 14
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
TIOC*B
Not initialized (TIOC*B)
Port output
PEn
High-Z
PEn
High-Z
n = 0 to 15
Figure 11.122 Error Occurrence in PWM Mode 1, Recovery in Phase Counting Mode
1 to 10 are the same as in figure 11.119.
11. Set phase counting mode.
12. Initialize the pins with TIOR.
13. Set MTU2 output with the PFC.
14. Operation is restarted by TSTR.
Note: Phase counting mode can only be set for channels 1 and 2, and therefore TOER setting is
not necessary.
Rev. 2.00 Mar. 14, 2008 Page 634 of 1824
REJ09B0290-0200