English
Language : 

SH7760 Datasheet, PDF (742/1345 Pages) Renesas Technology Corp – SuperHTM RISC engine
Bit
Bit Name Initial Value R/W Description
26
OIRQ
0
R/W* Overflow Error Interrupt Status Flag
This status flag indicates that the data has been
supplied at a higher rate than the required rate.
This bit is set to 1 regardless of the setting of
OIEN bit. In order to clear it to 0, write 0 in it.
If OIRQ = 1 and OIEN = 1, then an interrupt will
be generated.
When TRMD = 0 (Receive Mode):
If OIRQ = 1, it indicates that the previous unread
data had not been read out before new unread
data was written in SSIRDR. This may cause the
loss of data, which can lead to destruction of
multi-channel data.
When TRMD = 1 (Transmit Mode):
If OIRQ = 1, it indicates that SSITDR had data
written in before the data in SSITDR was
transferred to the shift register. This may cause
the loss of data, which can lead to destruction of
multi-channel data.
Note: When overflow error occurs, the data in
the data buffer will be overwritten by the
next data sent from the SSI interface.
25
IIRQ
1
R
Idle Mode Interrupt Status Flag
This status flag indicates whether the SSI module
is in the idle status. This bit is set to 1 regardless
of the setting of IIEN bit, so that polling will be
possible.
The interrupt can be masked by clearing IIEN bit
to 0, but writing 0 in this bit will not clear the
interrupt.
If IIRQ = 1 and IIEN = 1, then an interrupt will be
generated.
0: The SSI module is not in the idle status.
1: The SSI module is in the idle status.
Rev. 1.0, 02/03, page 692 of 1294