English
Language : 

SH7760 Datasheet, PDF (443/1345 Pages) Renesas Technology Corp – SuperHTM RISC engine
Bit
Bit Name Initial Value R/W Description
23
A1RXHF
0
R/W HAC(1)/SSI(1) Receive Side Half Data Transfer
End Interrupt Flag
0: An interrupt has not occurred.
[Clearing condition]
When 0 is written to A1RXHF after reading
A1RXHF = 1
1: An interrupt has occurred.
22
A1RXEF
0
R/W HAC(1)/SSI(1) Receive Side All Data Transfer End
Interrupt Flag
0: An interrupt has not occurred.
[Clearing condition]
When 0 is written to A1RXEF after reading
A1RXEF = 1
1: An interrupt has occurred.
21
A1TXHF
0
R/W HAC(1)/SSI(1) Transmit Side Half Data Transfer
End Interrupt Flag
0: An interrupt has not occurred.
[Clearing condition]
When 0 is written to A1TXHF after reading
A1TXHF = 1
1: An interrupt has occurred.
20
A1TXEF
0
R/W HAC(1)/SSI(1) Transmit Side All Data Transfer
End Interrupt Flag
0: An interrupt has not occurred.
[Clearing condition]
When 0 is written to A1TXEF after reading
A1TXEF = 1
1: An interrupt has occurred.
19
A0RXHF
0
R/W HAC(0)/SSI(0) Receive Side Half Data Transfer
End Interrupt Flag
0: An interrupt has not occurred.
[Clearing condition]
When 0 is written to A0RXHF after reading
A0RXHF = 1
1: An interrupt has occurred.
Rev. 1.0, 02/03, page 393 of 1294