|
SH7760 Datasheet, PDF (664/1345 Pages) Renesas Technology Corp – SuperHTM RISC engine | |||
|
◁ |
Bit
Bit Name
2 TEND
Initial
Value R/W Description
1
R
Transmit End
Indicates that transmission is ended.
The TEND flag is read-only, and cannot be written.
0: Indicates that transmission is in progress
[Clearing Condition]
⢠Transmit data is transferred from SITDR to SITSR, and
serial transmission is initiated.
1: Indicates that transmission is ended
[Setting Conditions]
⢠On reset
⢠When ERS = 0 (normal transmission) after transmission
of one byte of serial characters and a parity bit
Note: * The TEND flag is set 1 etu before the end of the
guardtime.
Rev. 1.0,02/03, page 614 of 1294
|
▷ |