FlexRay Communication Controller (FLEXRAY)
Field
RBIE
TBIE
Table 22-16. GIFER Field Descriptions (continued)
Description
Receive Buffer Interrupt Enable — This flag controls if the receive buffer interrupt line is asserted when the
RBIF flag is set.
0 Disable interrupt line
1 Enable interrupt line
Transmit Interrupt Enable — This flag controls if the transmit buffer interrupt line is asserted when the TBIF
flag is set.
0 Disable interrupt line
1 Enable interrupt line
22.5.2.11 Protocol Interrupt Flag Register 0 (PIFR0)
Base + 0x0018
Write: Normal Mode
0
1
2
3
4
5
6
7
8
9
10
11
12
13
R FATL INTL ILCF CSA MRC MOC CCL MXS MTX LTXB LTXA TBVB TBVA TI2
_IF _IF _IF _IF _IF _IF _IF _IF _IF _IF _IF _IF _IF _IF
14
15
TI1 CYS
_IF _IF
W w1c w1c w1c w1c w1c w1c w1c w1c w1c w1c w1c w1c w1c w1c w1c w1c
Reset 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Figure 22-11. Protocol Interrupt Flag Register 0 (PIFR0)
The register holds one set of the protocol-related individual interrupt flags.
Table 22-17. PIFR0 Field Descriptions
Field
FATL_IF
INTL_IF
ILCF_IF
Description
Fatal Protocol Error Interrupt Flag — This flag is set when the protocol engine has detected a fatal protocol
error. In this case, the protocol engine goes into the POC:halt state immediately. The fatal protocol errors are:
1) pLatestTx violation, as described in the MAC process of the FlexRay protocol
2) transmission across slot boundary violation, as described in the FSP process of the FlexRay protocol
0 No such event.
1 Fatal protocol error detected.
Internal Protocol Error Interrupt Flag — This flag is set when the protocol engine has detected an internal
protocol error. In this case, the protocol engine goes into the POC:halt state immediately. An internal protocol
error occurs when the protocol engine has not finished a calculation and a new calculation is requested. This
can be caused by a hardware error.
0 No such event.
1 Internal protocol error detected.
Illegal Protocol Configuration Interrupt Flag — This flag is set when the protocol engine has detected an
illegal protocol configuration parameter setting. In this case, the protocol engine goes into the POC:halt state
immediately.
The protocol engine checks the listen_timeout value programmed into the Protocol Configuration Register 14
(PCR14) and Protocol Configuration Register 15 (PCR15) when the CONFIG_COMPLETE command was sent
by the application via the Protocol Operation Control Register (POCR). If the value of listen_timeout is equal to
zero, the protocol configuration setting is considered as illegal.
0 No such event.
1 Illegal protocol configuration detected.
22-22