Error Correction Status Module (ECSM)
See Figure 17-4 and Table 17-6 for the ECC error generation register definition.
Offset: ECSM_BASE_ADDR + 0x004A
Access: User read/write
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
R0
W
0
0
FRC1BI FR11BI
0
0
FRCNCI FR1NCI
ERRBIT
Reset 0 0
0
0
00
0
0
00 0 0 0 0 0 0
Figure 17-4. ECC Error Generation (ECSM_EEGR) Register
Table 17-6. ECSM_EEGR Field Descriptions
Field
Description
0–1 Reserved
2
Force RAM Continuous 1-Bit Data Inversions. The assertion of this bit forces the RAM controller to create 1-bit data
FRC1BI inversions, as defined by the bit position specified in ERRBIT, continuously on every write operation.
The normal ECC generation takes place in the RAM controller, but then the polarity of the bit position defined by
ERRBIT is inverted to introduce a 1-bit ECC event in the RAM.
After this bit has been enabled to generate another continuous 1-bit data inversion, it must be cleared before being
set again to properly re-enable the error generation logic.
0 No RAM continuous 1-bit data inversions are generated.
1 1-bit data inversions in the RAM are continuously generated.
3
Force RAM One 1-bit Data Inversion. The assertion of this bit forces the RAM controller to create one 1-bit data
FR11BI inversion, as defined by the bit position specified in ERRBIT, on the first write operation after this bit is set.
The normal ECC generation takes place in the RAM controller, but then the polarity of the bit position defined by
ERRBIT is inverted to introduce a 1-bit ECC event in the RAM.
After this bit has been enabled to generate a single 1-bit data inversion, it must be cleared before being set again
to properly re-enable the error generation logic.
0 No RAM single 1-bit data inversion is generated.
1 One 1-bit data inversion in the RAM is generated.
4–5 Reserved
6
FRCNCI
Force RAM Continuous Noncorrectable Data Inversions. The assertion of this bit forces the RAM controller to create
2-bit data inversions, as defined by the bit position specified in ERRBIT and the overall odd parity bit, continuously
on every write operation.
After this bit has been enabled to generate another continuous noncorrectable data inversion, it must be cleared
before being set again to properly re-enable the error generation logic.
The normal ECC generation takes place in the RAM controller, but then the polarity of the bit position defined by
ERRBIT and the overall odd parity bit are inverted to introduce a 2-bit ECC error in the RAM.
0 No RAM continuous 2-bit data inversions are generated.
1 2-bit data inversions in the RAM are continuously generated.
17-8
PXR40 Microcontroller Reference Manual, Rev. 1