Fault Collection and Control Unit (FCCU)
Offset: 0x01C–0x028 (4 registers)
Access: User read/write1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
R
W
Reset 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
R
W
Reset 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12 0/12
1 Writable only in the CONFIG state
2 1 for FCCU_NCF_CFG0; 0 otherwise
Figure 22-6. FCCU NCF Configuration Register (FCCU_NCF_CFG0..3)
Table 22-7. FCCU_NCF_CFG0..3 field descriptions
Field
NCFCx
Non-critical fault configuration
0: HW recoverable fault
1: SW recoverable fault
Description
The non-critical fault configuration defines the fault recovery mode.
HW recoverable faults are self recovered (status flag clearing and related) if the root cause has
been removed.
SW recoverable faults are recovered (status flag clearing) by SW clearing of the related status
flag.
This register can be read and written by the software.
22.6.6 FCCU CFS Configuration Register (FCCU_CFS_CFG0..7)
The FCCU_CF_FS_CFGx register is accessible in write mode only in the CONFIG state. It contains the
configuration of each critical fault in terms of fault reaction (short or long ‘functional’ reset) when it is the
root cause for the FAULT state transition.
Freescale Semiconductor
PXS20 Microcontroller Reference Manual, Rev. 1
22-13