English
Language : 

PXS20RM Datasheet, PDF (507/1368 Pages) Freescale Semiconductor, Inc – PXS20 Microcontroller
Fault Collection and Control Unit (FCCU)
• Read or clear the FCCU freeze registers
• Lock the FCCU configuration registers
• Read the ALARM timer
• Read the SMRT timer
• Read the Watchdog timer
• Load the NVM configuration (only for test purposes)
Some critical operations (OP1, OP2, OP16, and OP31) require a key as defined in the FCCU_CTRLK
register.
Offset: 0x00
Access: User read/write
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
R0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
W
Reset 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
R
0000000
OPS
0
OPR
W
Reset 0
0
0
0
0
0
0 0/11 0/11 0/11 0
0
0
0
0
0
1 1 when NVM interface is used, 0 otherwise.
Figure 22-2. FCCU Control Register (FCCU_CTRL)
Table 22-3. FCCU_CTRL field descriptions
Field
NVML
OPS
Description
NVM configuration loaded
0 No NVM configuration loaded.
1 NVM configuration loaded.
At the end of the reset PHASE3, NVML = 1 and OPS = 11 if the NVM interface of the FCCU is
correctly driven by the SSCM interface.
This bit can be read and cleared (via OP15 operation) by the software.
Operation status
00 Idle.
01 In progress.
10 Aborted.
11 Successful.
This bit can be read and cleared (via OP15 operation) by the software.
Freescale Semiconductor
PXS20 Microcontroller Reference Manual, Rev. 1
22-7