PXS20RM Datasheet, PDF (501/1368 Pages) Freescale Semiconductor, Inc – PXS20 Microcontroller | |||
|
◁ |
Fault Collection and Control Unit (FCCU)
Chapter 22
Fault Collection and Control Unit (FCCU)
22.1 Introduction
The Fault Collection and Control Unit (FCCU) offers a programmable redundant hardware channel to
collect errors and to lead the device in a controlled way to a safe state when a failure is present in the
device. No CPU intervention is requested for collection and control operation.
The FCCU offers a systematic approach to manage fault detection and control.
The main functions supported by the module are:
⢠Redundant collection of hardware checker (for example, RCCU) results
⢠Redundant collection of error information from critical modules on the chip (such as the flash
memory or the STCU)
⢠Collection of test results
⢠Configurable and graded fault control via user software control
⢠Internal reactions:
â No reset reaction
â IRQ
â Short âfunctionalâ reset
â Long âfunctionalâ reset
â SAFE mode request
⢠External reaction (failure is reported to the outside world via output pins)
⢠Watchdog timer for the re-configuration phase
⢠Configuration lock
⢠NVM configuration loading
⢠Self checking capabilities:
â FCCU internal control logic redundancy
â Additional parity check for the associated configuration registers
The FCCU circuitry is checked at start-up by the self-checking procedure. The FCCU is operative with a
default configuration (without CPU intervention) immediately after the completion of the self-checking
procedure.
Two classes of faults â critical and non-critical â are identified based on the criticality and the related
reactions. Internal (short or long âfunctionalâ reset, interrupt request) and external (FCCU_F signaling)
reactions are statically defined or programmable based on the fault criticality. The default configuration
can be modified only in a specific FCCU state for application/test/debugging purposes.