PXD20RM Datasheet, PDF (987/1628 Pages) Freescale Semiconductor, Inc – PXD20 Microcontroller
27.10.4 LIN error status register (LINESR)
Offset: 0x0C
Access: User read/write
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
R0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
W
Reset 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
R
SZF
OCF
BEF
CEF
SFE
F
FEF BOF 0 0 0 0 0 0 NF
W w1c w1c w1c w1c w1c w1c w1c w1c w1c
w1c
Reset 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Figure 27-21. LIN error status register (LINESR)
Table 27-17. LINESR field descriptions
Field
SZF
OCF
BEF
CEF
SFEF
BDEF
Description
Stuck at zero Flag
This bit is set by hardware when the bus is dominant for more than a 100-bit time. It is cleared by
software.
Output Compare Flag
0: No output compare event occurred
1: The content of the counter has matched the content of OC1[0:7] or OC2[0:7] in LINOCR. If this bit
is set and IOT bit in LINTCSR is set, LINFlexD moves to Idle state.
If LTOM bit in LINTCSR register is set then OCF is reset by hardware in Initialization mode. If LTOM
bit is reset, then OCF maintains its status whatever the mode is.
Bit Error Flag
This bit is set by hardware and indicates to the software that LINFlexD has detected a bit error. This
error can occur during response field transmission (Slave and Master modes) or during header
transmission (in Master mode).
This bit is cleared by software.
Checksum error Flag
This bit is set by hardware and indicates that the received checksum does not match the hardware
calculated checksum.
This bit is cleared by software.
Note: This bit is never set if CCD or CFD bit in LINCR1 register is set.
Synch Field Error Flag
This bit is set by hardware and indicates that a Synch Field error occurred (inconsistent Synch Field).
Break Delimiter Error Flag
This bit is set by hardware and indicates that the received Break Delimiter is too short (less than one
bit time).