Section 17 Realtime Clock (RTC)
17.3.10 Minute Alarm Register (RMINAR)
RMINAR is an alarm register corresponding to the minute counter RMINCNT. When the ENB bit
is set to 1, a comparison with the RMINCNT value is performed. From among
RSECAR/RMINAR/RHRAR/RWKAR/RDAYAR/RMONAR/RCR3, the counter and alarm
register comparison is performed only on those with ENB bits set to 1, and if each of those
coincide, an alarm flag of RCR1 is set to 1.
The range of minute alarm, which can be set, is 00 to 59 (decimal). Errant operation will result if
any other value is set.
The ENB bit in RMINAR is initialized by a power-on reset. The remaining RMINAR fields are
not initialized by a power-on reset or manual reset, or in standby mode.
Bit: 7
6
5
4
3
2
1
0
ENB 10-minute units
1-minute units
Initial value: 0 — — — — — — —
R/W: R/W R/W R/W R/W R/W R/W R/W R/W
Bit
7
6 to 4
3 to 0
Initial
Bit Name Value
R/W
ENB
0
R/W

Undefined R/W

Undefined R/W
Description
When this bit is set to 1, a comparison with the
RMINCNT value is performed.
Ten’s position of minutes setting value
One’s position of minutes setting value