does not increment anymore by acknowledge errors. Therefore the device never goes to the ‘Bus
Off’ state.
• If the Rx_Err_Counter increases to a value greater than 127, it is not incremented further, even if
more errors are detected while being a receiver. At the next successful message reception, the
counter is set to a value between 119 and 127 to resume to ‘Error Active’ state.
Base + 0x001C
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15
R0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
RESET: 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
R
Rx_Err_Counter
Tx_Err_Counter
W
RESET: 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
= Unimplemented or Reserved
Figure 18-9. Error Counter Register (ECR)
18.3.4.8 Error and Status Register (ESR)
This register reflects various error conditions, some general status of the device and it is the source of four
interrupts to the CPU. The reported error conditions (bits 16-21) are those that occurred since the last time
the CPU read this register. The CPU read action clears bits 16-21. Bits 22-28 are status bits.
Most bits in this register are read only, except TWRN_INT, RWRN_INT, BOFF_INT and ERR_INT, that
are interrupt flags that can be cleared by writing ‘1’ to them (writing ‘0’ has no effect). See
Section 18.4.10, Interrupts for more details.
18-22
PXD10 Microcontroller Reference Manual, Rev. 1
Preliminary—Subject to Change Without Notice
Freescale Semiconductor