English
Language : 

PXD10RM Datasheet, PDF (384/1332 Pages) Freescale Semiconductor, Inc – PXD10 Microcontroller
Table 12-31. PDI Status Register field descriptions
Field
Description
22
pdi_blanking_err
Status bit to inform the software that 80h,10h sequence is not present during the blanking
period in internal sync mode.
1’b1:Correct data sequence not present in blanking period
1’b0:Correct data sequence present in blanking period
23
pdi_ecc_err2
Status bit to inform the software about multibit bit error that is detected.
1’b1: Multibit ECC error detected
1’b0: Multibit ECC error is not detected
24
pdi_ecc_err1
Status bit to inform the software about one bit error is detected.
1’b1: One bit ECC error detected
1’b0: One bit ECC error is not detected
25
pdi_lock_lost
Status bit to inform the software that frame lock is lost.
1’b1: Frame lock is lost
1’b0: Frame is locked
26
pdi_lock_det
Status bit to inform the software PDI is frame locked to the camera interface.
1’b1: Frame lock is detected
1’b0: Waiting for frame to lock
27
pdi_vsync_det
Status bit to inform the software that vsync for the camera data has been detected.
1’b1: pdi_vsync is detected
1’b0: pdi_vsync not detected
28
pdi_hsync_det
Status bit to inform the software that hsync for the camera data has been detected.
1’b1: pdi_hsync is detected
1’b0: pdi_hsync not detected
29
pdi_de_det
Status bit to inform the software that data Enable for the camera data has been detected.
1’b1: pdi_de is detected
1’b0: pdi_de not detected
30
pdi_clk_lost
Status bit to inform the software that pdi_clk is lost
1’b1: pdi_clk is lost
1’b0: pdi_clk is present
31
pdi_clk_det
Status bit to inform the software that clock for the camera data has been detected.
1’b1: pdi_clk is detected
1’b0: pdi_clk not detected
12.3.4.27 PDI Status Mask Register
Figure 12-37 represents the Mask PDI status register
12-52
PXD10 Microcontroller Reference Manual, Rev. 1
Preliminary—Subject to Change Without Notice
Freescale Semiconductor