English
Language : 

PXD10RM Datasheet, PDF (1186/1332 Pages) Freescale Semiconductor, Inc – PXD10 Microcontroller
Start of Measurement1
Initialize SSD2
Start Blanking3
End of
Blanking?4 No
Yes
Start Integration5
BIS executed
automatically
InEtengdraotfion?6 No
Yes
Stop Integration7
Read Integration Result8
End of Measurement9
Figure 36-12. Generic SSD Flow
36.4.2.2 Details of the SSD Measurement
This section describes in detail the steps introduced in Figure 36-12. Note that it describes only the
measurement process. The decision whether the stall position has been reached or another SM step is
required must be made by the controlling CPU depending from the measurement result. All control bits
are assumed to have their (inactive) reset values prior to entering the SSD measurement flow. The
following paragraphs relate to one complete BIS including the (optional) blanking phase followed by the
integration phase:
1. Start of Measurement
36-20
PXD10 Microcontroller Reference Manual, Rev. 1
Preliminary—Subject to Change Without Notice