Section 18 Serial Communication Interface with FIFO (SCIF)
Bit Bit Name Initial Value R/W Description
2
PER
0
R
Parity Error
Indicates a parity error in the data read from the
receive FIFO data register (SCFRDR) in
asynchronous mode.
0: No parity error occurred in the data read from
SCFRDR
[Clearing conditions]
• Power-on reset, manual reset
• No parity error is present in the data read from
SCFRDR
1: A parity error occurred in the data read from
SCFRDR
[Setting condition]
• A parity error is present in the data read from
SCFRDR
Rev. 3.00 Jan. 18, 2008 Page 604 of 1458
REJ09B0033-0300