11. Advanced Timer Unit-II (ATU-II)
• Bit 13—One-Shot Pulse Terminate Enable N (OTEN): Enables or disables forced termination of output by channel 2
down-counter terminate trigger F.
Bit 13: OTEN
0
1
Description
Forced termination of TO8N by down-counter terminate trigger is disabled
Forced termination of TO8N by down-counter terminate trigger is enabled
(Initial value)
• Bit 12—One-Shot Pulse Terminate Enable M (OTEM): Enables or disables forced termination of output by channel 2
down-counter terminate trigger E.
Bit 12: OTEM
0
1
Description
Forced termination of TO8M by down-counter terminate trigger is disabled
Forced termination of TO8M by down-counter terminate trigger is enabled
(Initial value)
• Bit 11—One-Shot Pulse Terminate Enable L (OTEL): Enables or disables forced termination of output by channel 2
down-counter terminate trigger D.
Bit 11: OTEL
0
1
Description
Forced termination of TO8L by down-counter terminate trigger is disabled
Forced termination of TO8L by down-counter terminate trigger is enabled
(Initial value)
• Bit 10—One-Shot Pulse Terminate Enable K (OTEK): Enables or disables forced termination of output by channel 2
down-counter terminate trigger C.
Bit 10: OTEK
0
1
Description
Forced termination of TO8K by down-counter terminate trigger is disabled
Forced termination of TO8K by down-counter terminate trigger is enabled
(Initial value)
• Bit 9—One-Shot Pulse Terminate Enable J (OTEJ): Enables or disables forced termination of output by channel 2
down-counter terminate trigger B.
Bit 9: OTEJ
0
1
Description
Forced termination of TO8J by down-counter terminate trigger is disabled
Forced termination of TO8J by down-counter terminate trigger is enabled
(Initial value)
• Bit 8—One-Shot Pulse Terminate Enable I (OTEI): Enables or disables forced termination of output by channel 2
down-counter terminate trigger A.
Bit 8: OTEI
0
1
Description
Forced termination of TO8I by down-counter terminate trigger is disabled
Forced termination of TO8I by down-counter terminate trigger is enabled
(Initial value)