English
Language : 

SH7059 Datasheet, PDF (26/1042 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer
Differences between SH7058 and SH7058S/SH7059
SH7058 (Rev.3, REJ09B0046-0300H)
SH7058S/SH7059
17.6 Usage Notes
648
2. Relation between, AVSS, AVCC and VSS, VCC
When using the A/D converter, set AVCC = 5.0 V ±0.5 V,
and AV = V . When the A/D converter is not used, set
SS
SS
AVSS = VSS, and do not leave the AVCC pin open.
3. AVref input range
Set AV = 4.5 V to AV when the A/D converter is used,
ref
CC
and AVref ≤ AVCC when not used.
If conditions above are not met, the reliability of the device
may be adversely affected.
18.6 Usage Notes
Description amended
2. Relation between, AVSS, AVCC and VSS, VCC
When using the A/D converter, set AVCC = 5.0 V ±0.5 V,
and AV = V . When the A/D converter is not used, set
SS
SS
AVSS = VSS, and the setting range is AVSS ≤ AVCC ≤ 5.5 V.
3. AVref input range
Set AV = 4.5 V to AV when the A/D converter is used,
ref
CC
and AVCC - 1.0 V ≤ AVref ≤ AVCC and AVSS ≤ AVref when not
used.
If conditions above are not met, the reliability of the device
may be adversely affected.
18.3 Interrupt Interface
Deleted
18.4 PFC and I/O Port Interfaces
Deleted
18.6 Appendices
Deleted
19.1.4 Register Configuration
Table 19.2 Register Configuration
697
20.1.4 Register Configuration
Table 20.2 Register Configuration
Table and note amended
Register
Status register
ID code register
Abbreviation Initial Value*2
SDSR
H'0B01
SDIDR
H'001D200F
Register
Status register
ID code register
Abbreviation
SDSR
SDIDR
Initial Value*2
H'5001 (SH7058SF)
H'0F01 (SH7059F)
H'08016447 (SH7058SF)
H'0800B447 (SH7059F)
Notes:
2. Initial value when the TRST signal is input. Registers are
not initialized by a reset (power-on or manual) or in standby
mode.
Notes:
2. Initial value when the TRST signal is input. Registers are
not initialized by a reset (power-on or manual) .
19.3.1 Instruction Register (SDIR)
699
SDIR can be initialized by the TRST signal, but is not
initialized by a reset or in software standby mode.
20.3.1 Instruction Register (SDIR)
Description amended
SDIR can be initialized by the TRST signal or in software
standby mode, but is not initialized by a reset .
Rev.3.00 Mar. 12, 2008 Page xxvi of xc
REJ09B0177-0300