11. Advanced Timer Unit-II (ATU-II)
11.2.12 Timer Connection Register (TCNR)
The timer connection register (TCNR) is a 16-bit register. The ATU-II has one TCNR register in channel 8.
Bit:
Initial value:
R/W:
15
CN8P
0
R/W
14
CN8O
0
R/W
13
CN8N
0
R/W
12
CN8M
0
R/W
11
CN8L
0
R/W
10
CN8K
0
R/W
9
CN8J
0
R/W
8
CN8I
0
R/W
Bit:
Initial value:
R/W:
7
CN8H
0
R/W
6
CN8G
0
R/W
5
CN8F
0
R/W
4
CN8E
0
R/W
3
CN8D
0
R/W
2
CN8C
0
R/W
1
CN8B
0
R/W
0
CN8A
0
R/W
TCNR is a 16-bit readable/writable register that enables or disables connection between the channel 8 down-count start
register (DSTR) and channel 1 and 2 compare-match signals (down-count start triggers). Channel 1 down-count start
triggers A to H are channel 1 OCR1 compare-match signals or GR1x compare-match signals (set in TRGMDR). Channel
2 down-count start triggers A to H are channel 2 OCR2x compare-match signals. When GR1x compare-matches are used,
set TIOR1A to TIOR1D to allow compare-matches.
TCNR is initialized to H'0000 by a power-on reset, and in hardware standby mode and software standby mode.
For details, see sections 11.3.5, One-Shot Pulse Function, and 11.3.6, Offset One-Shot Pulse Function and Output Cutoff
Function.
• Bit 15—Connection Flag 8P (CN8P): Enables or disables connection between DST8P and the channel 2 down-count
start trigger.
Bit 15: CN8P
0
1
Description
Connection between DST8P and channel 2 down-count start trigger H is disabled
(Initial value)
Connection between DST8P and channel 2 down-count start trigger H is enabled
• Bit 14—Connection Flag 8O (CN8O): Enables or disables connection between DST8O and the channel 2 down-count
start trigger.
Bit 14: CN8O
0
1
Description
Connection between DST8O and channel 2 down-count start trigger G is disabled
(Initial value)
Connection between DST8O and channel 2 down-count start trigger G is enabled
• Bit 13—Connection Flag 8N (CN8N): Enables or disables connection between DST8N and the channel 2 down-count
start trigger.
Bit 13: CN8N
0
1
Description
Connection between DST8N and channel 2 down-count start trigger F is disabled
(Initial value)
Connection between DST8N and channel 2 down-count start trigger F is enabled
Rev.3.00 Mar. 12, 2008 Page 253 of 948
REJ09B0177-0300