CHAPTER 14 SERIAL ARRAY UNIT
Table 14-10. Relationship between register settings and pins (Channel 1 of unit 1: UART2 reception)
SE11 Note1
MD112
0
0
1
0
MD111
1
1
TXE11
0
0
RXE11
0
1
PM11 Note2
×Note3
1
P11 Note2
Operation
mode
×Note3
×
Operation
stop mode
UART2
reception
Note4, 5
Pin Function
SI20/SDA20/RxD2/
INTP6/P11 Note2
SI20/SDA20/INTP6/P11
RxD2
Notes 1. The SE1 register is a read-only status register which is set using the SS1 and ST1 registers.
2. When channel 1 of unit 1 is set to UART2 reception, this pin becomes an RxD2 function pin. In this case, set
channel 0 of unit 1 to operation stop mode or UART2 transmission (refer to Table 14-9).
When channel 0 of unit 1 is set to CSI20 or IIC20, this pin cannot be used as an RxD2 function pin. In this case,
set channel 1 of unit 1 to operation stop mode.
3. This pin can be set as a port function pin.
4. When using UART2 transmission and reception in a pair, set channel 0 of unit 1 to UART2 transmission (refer to
Table 14-9).
5. The SMR10 register of channel 0 of unit 1 must also be set during UART2 reception. For details, refer to 14.5.2
(1) Register setting.
Remark X: Don’t care