English
Language : 

UPD78F1502AGK-GAK-AX Datasheet, PDF (591/1031 Pages) Renesas Technology Corp – 16-Bit Single-Chip Microcontrollers
78K0R/Lx3
CHAPTER 14 SERIAL ARRAY UNIT
Table 14-9. Relationship between register settings and pins
(Channel 0 of unit 1: CSI20, UART2 transmission, IIC20)
SE MD MD SOE SO CKO TXE RXE PM P10 PM P11 PM P12
10 102 101 10 10 10 10 10 10
11 Note2 12
Note1
Note2
Operation mode
Pin Function
SCK20/ SI20/SDA20/ SO20/
SCL20/P10 RxD2/INTP6/ TxD2/
P11 Note2 TO02/P12
000 0 1 1 0 0 × × × × × ×
Operation stop
01
Note3 Note3 Note3 Note3 Note3 Note3
mode
10
P10
INTP6/P11 TO02/P12
RxD2/INTP6/
P11
INTP6/P11
100
01
010
1
0
0110
1 0/1 1 1
Note4
1 0/1 1 1
Note4
0 1 0/1 0
Note4
1 0/1 0/1 1
Note4 Note4
1 0/1 0/1 1
Note4 Note4
1 0/1 1 1
Note4
0 0/1 0/1 0
Note6 Note6
1
0
1 0/1 0/1 1
Note4 Note4
1 0/1 0/1 1
Note4 Note4
1 0/1 0/1 0
Note4 Note4
0 0/1 0/1 0
Note7 Note7
1
0
11 × 1×× ×
Note3 Note3
Slave CSI20
reception
01 × ××0 1
Note3 Note3
Slave CSI20
transmission
11 × 1×0 1
Slave CSI20
transmission/reception
10 1
1×× ×
Note3 Note3
Master CSI20
reception
00 1 ××0 1
Note3 Note3
Master CSI20
transmission
10 1 1×0 1
Master CSI20
transmission/reception
0× × ××0 1
Note3 Note3 Note3 Note3
UART2
transmissionNote5
00 1 01× ×
IIC20
Note3 Note3
0
start condition
1
0 0 1 0 1 × × IIC20 address field
Note3 Note3
transmission
00 1 01× ×
Note3 Note3
IIC20 data
transmission
10 1 01× ×
Note3 Note3
IIC20 data
reception
00 1
0
01× ×
Note3 Note3
IIC20
stop condition
1
SCK20
(input)
SCK20
(input)
SCK20
(input)
SCK20
(output)
SCK20
(output)
SCK20
(output)
P10
SCL20
SCL20
SCL20
SCL20
SCL20
SI20
TO02/P12
INTP6/P11 SO20
SI20
SO20
SI20
TO02/P12
INTP6/P11 SO20
SI20
SO20
RxD2/INTP6/
P11
TxD2
SDA20 TO02/P12
SDA20 TO02/P12
SDA20 TO02/P12
SDA20 TO02/P12
SDA20 TO02/P12
Notes 1. The SE1 register is a read-only status register which is set using the SS1 and ST1 registers.
2. When channel 1 of unit 1 is set to UART2 reception, this pin becomes an RxD2 function pin (refer to Table 14-
10). In this case, operation stop mode or UART2 transmission must be selected for channel 0 of unit 1.
3. This pin can be set as a port function pin.
4. This is 0 or 1, depending on the communication operation. For details, refer to 14.3 (12) Serial output register
m (SOm).
5. When using UART2 transmission and reception in a pair, set channel 1 of unit 1 to UART2 reception (refer to
Table 14-10).
6. Set the CKO10 bit to 1 before a start condition is generated. Clear the SO10 bit from 1 to 0 when the start
condition is generated.
7. Set the CKO10 bit to 1 before a stop condition is generated. Clear the SO10 bit from 0 to 1 when the stop
condition is generated.
Remark X: Don’t care
R01UH0004EJ0501 Rev.5.01
575
Jun 20, 2011