English
Language : 

PXN20RM Datasheet, PDF (638/1376 Pages) Freescale Semiconductor, Inc – PXN20 Microcontroller
FlexRay Communication Controller (FlexRAY)
Table 26-17. PIFR0 Field Descriptions (continued)
Field
CCL_IF
MXS_IF
MTX_IF
LTXB_IF
LTXA_IF
TBVB_IF
TBVA_IF
TI2_IF
TI1_IF
CYS_IF
Description
Clock Correction Limit Reached Interrupt Flag — This flag is set when the internal calculated offset or rate
calculation values have reached or exceeded its configured thresholds as given by the offset_coorection_out
field in the Protocol Configuration Register 9 (PCR9) and the rate_correction_out field in the Protocol
Configuration Register 14 (PCR14).
0 No such event.
1 Offset or rate correction limit reached.
Max Sync Frames Detected Interrupt Flag — This flag is set when the number of synchronization frames
detected in the current communication cycle exceeds the value of the node_sync_max field in the Protocol
Configuration Register 30 (PCR30).
0 No such event.
1 More than node_sync_max sync frames detected.
Note: Only synchronization frames that have passed the synchronization frame acceptance and rejection filters
are taken into account.
Media Access Test Symbol Received Interrupt Flag — This flag is set when the MTS symbol was received
on channel A or channel B.
0 No such event.
1 MTS symbol received.
pLatestTx Violation on Channel B Interrupt Flag — This flag is set when the frame transmission on channel B
in the dynamic segment exceeds the dynamic segment boundary. This is related to the pLatestTx violation, as
described in the MAC process of the FlexRay protocol.
0 No such event.
1 pLatestTx violation occurred on channel B.
pLatestTx Violation on Channel A Interrupt Flag — This flag is set when the frame transmission on channel A
in the dynamic segment exceeds the dynamic segment boundary. This is related to the pLatestTx violation as
described in the MAC process of the FlexRay protocol.
0 No such event.
1 pLatestTx violation occurred on channel A.
Transmission across boundary on channel B Interrupt Flag — This flag is set when the frame transmission
on channel B crosses the slot boundary. This is related to the transmission across slot boundary violation as
described in the FSP process of the FlexRay protocol.
0 No such event.
1 Transmission across boundary violation occurred on channel B.
Transmission across boundary on channel A Interrupt Flag — This flag is set when the frame transmission
on channel A crosses the slot boundary. This is related to the transmission across slot boundary violation as
described in the FSP process of the FlexRay protocol.
0 No such event.
1 Transmission across boundary violation occurred on channel A.
Timer 2 Expired Interrupt Flag — This flag is set whenever timer 2 expires.
0 No such event.
1 Timer 2 has reached its time limit.
Timer 1 Expired Interrupt Flag — This flag is set whenever timer 1 expires.
0 No such event
1 Timer 1 has reached its time limit
Cycle Start Interrupt Flag — This flag is set when a communication cycle starts.
0 No such event
1 Communication cycle started.
26-24
PXN20 Microcontroller Reference Manual, Rev. 1
Freescale Semiconductor