English
Language : 

SH7080_09 Datasheet, PDF (730/1622 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH RISC engine Family
Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
Operation when Error Occurs during Reset-Synchronized PWM Mode Operation, and
Operation is Restarted in Reset-Synchronized PWM Mode: Figure 11.165 shows an
explanatory diagram of the case where an error occurs in reset-synchronized PWM mode and
operation is restarted in reset-synchronized PWM mode after re-setting.
1
2
3
4
5
6
7
8
9
10
11
12
13
RESET TOCR TMDR TOER PFC TSTR Match Error PFC TSTR PFC TSTR Match
(RPWM) (1) (MTU2) (1)
occurs (PORT) (0) (MTU2) (1)
MTU2 module output
TIOC3A
TIOC3B
TIOC3D
Port output
PE8
Hi-Z
PE9
Hi-Z
PE11
Hi-Z
Figure 11.165 Error Occurrence in Reset-Synchronized PWM Mode,
Recovery in Reset-Synchronized PWM Mode
1 to 10 are the same as in figure 11.162.
11. Set MTU2 output with the PFC.
12. Operation is restarted by TSTR.
13. The reset-synchronized PWM waveform is output on compare-match occurrence.
Rev. 4.00 Dec. 15, 2009 Page 670 of 1558
REJ09B0181-0400