English
Language : 

SH7080_09 Datasheet, PDF (584/1622 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH RISC engine Family
Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
Example of Synchronous Operation: Figure 11.13 shows an example of synchronous operation.
In this example, synchronous operation and PWM mode 1 have been designated for channels 0 to
2, TGRB_0 compare match has been set as the channel 0 counter clearing source, and
synchronous clearing has been set for the channel 1 and 2 counter clearing source.
Three-phase PWM waveforms are output from pins TIOC0A, TIOC1A, and TIOC2A. At this
time, synchronous presetting, and synchronous clearing by TGRB_0 compare match, are
performed for channel 0 to 2 TCNT counters, and the data set in TGRB_0 is used as the PWM
cycle.
For details of PWM modes, see section 11.4.5, PWM Modes.
TCNT_0 to TCNT_2
values
TGRB_0
TGRB_1
TGRA_0
TGRB_2
TGRA_1
TGRA_2
H'0000
Synchronous clearing by TGRB_0 compare match
Time
TIOC0A
TIOC1A
TIOC2A
Figure 11.13 Example of Synchronous Operation
Rev. 4.00 Dec. 15, 2009 Page 524 of 1558
REJ09B0181-0400