English
Language : 

SH7080_09 Datasheet, PDF (709/1622 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH RISC engine Family
Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
Operation when Error Occurs during PWM Mode 1 Operation, and Operation is Restarted
in PWM Mode 1: Figure 11.144 shows an explanatory diagram of the case where an error occurs
in PWM mode 1 and operation is restarted in PWM mode 1 after re-setting.
MTU2 module output
TIOC*A
1
2
3
RESET TMDR TOER
(PWM1) (1)
4
5
6
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
7
Match
8
9
10 11 12 13
Error PFC TSTR TMDR TIOR PFC
occurs (PORT) (0) (PWM1) (1 init (MTU2)
0 out)
14
TSTR
(1)
TIOC*B
Not initialized (TIOC*B)
Not initialized (TIOC*B)
Port output
PEn
Hi-Z
PEn
Hi-Z
n = 0 to 15
Figure 11.144 Error Occurrence in PWM Mode 1, Recovery in PWM Mode 1
1 to 10 are the same as in figure 11.143.
11. Not necessary when restarting in PWM mode 1.
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC*B side is not initialized.)
13. Set MTU2 output with the PFC.
14. Operation is restarted by TSTR.
Rev. 4.00 Dec. 15, 2009 Page 649 of 1558