Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
Operation when Error Occurs during Complementary PWM Mode Operation, and
Operation is Restarted in PWM Mode 1: Figure 11.158 shows an explanatory diagram of the
case where an error occurs in complementary PWM mode and operation is restarted in PWM
mode 1 after re-setting.
MTU2 module output
1
2
3
4
5
6
RESET TOCR TMDR TOER PFC TSTR
(CPWM) (1) (MTU2) (1)
7
8
9
10
11
12
13
14
Match Error PFC TSTR TMDR TIOR PFC TSTR
occurs (PORT) (0) (PWM1) (1 init (MTU2) (1)
0 out)
TIOC3A
TIOC3B
Not initialized (TIOC3B)
TIOC3D
Port output
PE8
Hi-Z
PE9
Hi-Z
Not initialized (TIOC3D)
PE11
Hi-Z
Figure 11.158 Error Occurrence in Complementary PWM Mode,
Recovery in PWM Mode 1
1 to 10 are the same as in figure 11.157.
11. Set PWM mode 1. (MTU2 output goes low.)
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC *B side is not initialized.)
13. Set MTU2 output with the PFC.
14. Operation is restarted by TSTR.
Rev. 4.00 Dec. 15, 2009 Page 663 of 1558