Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
Operation when Error Occurs during Phase Counting Mode Operation, and Operation is
Restarted in PWM Mode 2: Figure 11.155 shows an explanatory diagram of the case where an
error occurs in phase counting mode and operation is restarted in PWM mode 2 after re-setting.
1
2
RESET TMDR
(PCM)
3
4
5
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
6
Match
7
8
9
10 11 12 13
Error PFC TSTR TMDR TIOR PFC TSTR
occurs (PORT) (0) (PWM2) (1 init (MTU2) (1)
0 out)
MTU2 module output
TIOC*A
Not initialized (cycle register)
TIOC*B
Port output
PEn
Hi-Z
PEn
Hi-Z
n = 0 to 15
Figure 11.155 Error Occurrence in Phase Counting Mode, Recovery in PWM Mode 2
1 to 9 are the same as in figure 11.153.
10. Set PWM mode 2.
11. Initialize the pins with TIOR. (In PWM mode 2, the cycle register pins are not initialized.)
12. Set MTU2 output with the PFC.
13. Operation is restarted by TSTR.
Rev. 4.00 Dec. 15, 2009 Page 660 of 1558
REJ09B0181-0400