English
Language : 

SH7785 Datasheet, PDF (837/1692 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer
18. Timer Unit (TMU)
18.3.4 Timer Control Registers (TCRn) (n = 0 to 5)
The TCR registers are 16-bit readable/writable registers. Each TCR selects the count clock,
specifies the edge when an external clock is selected, and controls interrupt generation when the
flag indicating TCNT underflow is set to 1. TCR2 is also used for input capture control and
control of interrupt generation in the event of input capture.
• TCR0, TCR1, TCR3, TCR4 and TCR5
BIt: 15 14 13 12 11 10 9 8 7
— — — — — — — UNF —
Initial value: 0
0
0
0
0
0
0
0
0
R/W: R R R R R R R R/W R
6
5
4
3
2
1
0
— UNIE CKEG1 CKEG0 TPSC2 TPSC1 TPSC0
0
0
0
0
0
0
0
R R/W R/W R/W R/W R/W R/W
• TCR2
BIt: 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
— — — — — — ICPF UNF ICPE1 ICPE0 UNIE CKEG1 CKEG0 TPSC2 TPSC1 TPSC0
Initial value: 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
R/W: R R R R R R R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
Initial
Bit
Bit Name Value R/W Description
15 to 10 —
9
ICPF*1
All 0 R
Reserved
These bits are always read as 0. The write value should
always be 0.
0
R/W Input Capture Interrupt Flag
Status flag, provided in channel 2 only, which indicates
the occurrence of input capture.
0: Input capture has not occurred
[Clearing condition]
When 0 is written to ICPF
1: Input capture has occurred
[Setting condition]
When input capture occurs*2
8
UNF
0
R/W Underflow Flag
Status flag that indicates the occurrence of TCNT
underflow.
0: TCNT has not underflowed
[Clearing condition]
When 0 is written to UNF
1: TCNT has underflowed
[Setting condition]
When TCNT underflows*2
Rev.1.00 Jan. 10, 2008 Page 807 of 1658
REJ09B0261-0100