21. Serial Communication Interface with FIFO (SCIF)
In serial reception, the SCIF operates as follows.
1. The SCIF monitors the transmission line, and if a 0-start bit is detected, performs internal
synchronization and starts reception.
2. The received data is stored in SCRSR in LSB-to-MSB order.
3. The parity bit and stop bit are received.
After receiving these bits, the SCIF carries out the following checks.
(a) Stop bit check: The SCIF checks whether the stop bit is 1. If there are two stop bits, only
the first is checked.
(b) The SCIF checks whether receive data can be transferred from SCRSR to SCFRDR.*
(c) Overrun error check: The SCIF checks that the ORER flag is 0, indicating that no overrun
error has occurred.*
(d) Break check: The SCIF checks that the BRK flag is 0, indicating that the break state is not
set.*
If (b), (c), and (d) checks are passed, the receive data is stored in SCFRDR.
Note: * Reception continues even when a parity error or framing error occurs.
4. If the RIE bit in SCSCR is set to 1 when the RDF or DR flag changes to 1, a receive-FIFO-
data-full interrupt (RXI) request is generated.
If the RIE bit or REIE bit in SCSCR is set to 1 when the ER flag changes to 1, a receive-error
interrupt (ERI) request is generated.
If the RIE bit or REIE bit in SCSCR is set to 1 when the BRK or ORER flag changes to 1, a
break reception interrupt (BRI) request is generated.
Figure 21.13 shows an example of the operation for reception in asynchronous mode.
Start
1 bit
Serial
data
0 D0
SCIF_RXD
RDF
Data
Parity Stop Start
bit bit bit
Data
Parity Stop
bit bit
D1
D7 0/1 1 0 D0 D1
D7 0/1 0
0/1
Framing error
detected
FER
RXI interrupt
request
One frame
Data read and RDF flag
read as 1 then cleared to
0 by RXI interrupt handler
ERI interrupt request
generated by receive
error
Figure 21.13 Example of SCIF Receive Operation
(Example with 8-Bit Data, Parity, One Stop Bit)
Rev.1.00 Jan. 10, 2008 Page 1083 of 1658