EHCI Controller Registers (D29:F7)
Bit
Description
4 Reserved
3
PME Clock (PME_CLK) â R/W (special). The ICH7 reports 0, indicating that no PCI
clock is required to generate PME#.
2:0
Version (VER) â R/W (special). The ICH7 reports 010b, indicating that it complies
with Revision 1.1 of the PCI Power Management Specification.
NOTES:
1.
Normally, this register is read-only to report capabilities to the power management
software. To report different power management capabilities, depending on the system in
which the ICH7 is used, bits 15:11 and 8:6 in this register are writable when the
WRT_RDONLY bit (D29:F7:80h, bit 0) is set. The value written to this register does not
affect the hardware other than changing the value returned during a read.
2.
Reset: core well, but not D3-to-D0 warm reset.
13.1.19 PWR_CNTL_STSâPower Management Control/
Status Register (USB EHCIâD29:F7)
Address Offset: 54hâ55h
Default Value: 0000h
Attribute:
Size:
R/W, R/WC, RO
16 bits
Bit
Description
PME Status â R/WC.
0 = Writing a 1 to this bit will clear it and cause the internal PME to deassert (if
enabled).
15 1 = This bit is set when the Intel® ICH7 EHC would normally assert the PME# signal
independent of the state of the PME_En bit.
NOTE: This bit must be explicitly cleared by the operating system each time the
operating system is loaded.
14:13
Data Scale â RO. Hardwired to 00b indicating it does not support the associated Data
register.
12:9
Data Select â RO. Hardwired to 0000b indicating it does not support the associated
Data register.
PME Enable â R/W.
0 = Disable.
1 = Enable. Enables ICH7 EHC to generate an internal PME signal when PME_Status is
8
1.
NOTE: This bit must be explicitly cleared by the operating system each time it is
initially loaded.
7:2 Reserved
Intel ® ICH7 Family Datasheet