Command H'43
 Command: H'43 (one byte): User MAT programming selection
Response H'06
 Response: H'06 (one byte): Response to user MAT programming selection
When the programming program has been transferred, the boot program will return ACK.
Error response H'C3 ERROR
 Error response: H'C3 (one byte): Error response to user MAT programming selection
 ERROR: (one byte): Error code
H'54: Selection processing error (transfer error occurs and processing is not completed)
(3) Two-user-MAT simultaneous programming selection
The boot program will transfer the two-user-MAT simultaneous programming program. Data
is simultaneously programmed to the two user MATs by the transferred two-user-MAT
simultaneous programming program. The host must alternately send addresses and data that
correspond to each MAT for simultaneous programming to two user MATs. The boot
program will return one ACK for one 128-byte programming command, however,
programming of the data will start when the boot program has received data for both MATs.
Command H'44
 Command: H'44 (one byte): Two-user-MAT simultaneous programming selection
Response H'06
 Response: H'06 (one byte): Response to two-user-MAT simultaneous programming
selection
After the two-user-MAT simultaneous programming program has been transferred, the
boot program will return ACK.
Error response H'C4 ERROR
 Error response: H'C4 (one byte): Error response to two-user-MAT simultaneous
programming selection
 ERROR: (one byte): Error code
H'54: Selection processing error (transfer error occurs and processing is not completed)
(4) 128-byte programming
The boot program will use the programming program transferred by the programming
selection command for programming the user boot MATs or user MATs. When two-user-
MAT simultaneous programming command is selected, programming will start after the boot
program has received data for both MATs.
Command H'50 Programming address
Data ...
...
SUM
 Command: H'50 (one byte): 128-byte programming
Rev.2.0, 07/03, page 823 of 960