English
Language : 

SH7055S Datasheet, PDF (801/1002 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH RISC engine Family/SH7000 Series
Bit 2—Write Data Address Detect (WD): When an address in the flash memory area is specified
as the start address of the storage destination of the program data, an error occurs.
Bit 2
WD
0
1
Description
Setting of write data address is normal
Setting of write data address is abnormal
Bit 1—Write Address Error Detect (WA): When the following items are specified as the start
address of the programming destination, an error occurs.
1. The programming destination address is an area other than flash memory
2. The specified address is not at the 128-byte boundary (A6 to A0 are not 0)
Bit 1
WA
0
1
Description
Setting of programming destination address is normal
Setting of programming destination address is abnormal
Bit 0—Success/Fail (SF): Indicates whether the program processing has ended normally or not.
Bit 0
SF
0
1
Description
Programming has ended normally (no error)
Programming has ended abnormally (error occurs)
(4) Erasure Execution
When flash memory is erased, the erase-block number on the user MAT must be passed to the
erasing program which is downloaded. This is set to the FEBS parameter (general register R4).
One block is specified from the block number 0 to 15.
For details on the erasing procedure, see section 22.5.2, User Program Mode.
Rev.2.0, 07/03, page 763 of 960