English
Language : 

HD64F2638F20J Datasheet, PDF (709/1512 Pages) Renesas Technology Corp – Renesas 16-Bit Single-Chip Microcomputer H8S Family/H8S/2600 Series
H8S/2639, H8S/2638, H8S/2636,
H8S/2630, H8S/2635 Group
Section 16 Controller Area Network (HCAN)
16.3.3 Transmit Mode
Message transmission is performed using mailboxes 1 to 15. The transmission procedure is
described below, and a transmission flowchart is shown in figure 16-6.
Initialization (after hardware reset only)
a. Clearing of IRR0 bit in interrupt register (IRR)
b. Bit rate settings
c. Mailbox transmit/receive settings
d. Mailbox (RAM) initialization
e. Message transmission method setting
Interrupt and transmit data settings
a. CPU interrupt source setting
b. Arbitration field setting
c. Control field setting
d. Data field setting
Message transmission and interrupts
a. Message transmission wait
b. Message transmission completion and interrupt
c. Message transmission cancellation
d. Message retransmission
Initialization (After Hardware Reset Only): These settings should be made while the HCAN is
in bit configuration mode.
• IRR0 clearing
The reset interrupt flag (IRR0) is always set after a reset or recovery from software standby
mode. As an HCAN interrupt is initiated immediately when interrupts are enabled, IRR0
should be cleared.
• Bit rate settings
Set values relating to the CAN bus communication speed and resynchronization. Refer to Bit
Rate and Bit Timing Settings in 16.3.2, Initialization after Hardware Reset, for details.
REJ09B0103-0800 Rev. 8.00
May 28, 2010
Page 659 of 1458