English
Language : 

HD64F2638F20J Datasheet, PDF (429/1512 Pages) Renesas Technology Corp – Renesas 16-Bit Single-Chip Microcomputer H8S Family/H8S/2600 Series
H8S/2639, H8S/2638, H8S/2636,
H8S/2630, H8S/2635 Group
Section 10 16-Bit Timer Pulse Unit (TPU)
Input Capture/Compare Match Interrupt: An interrupt is requested if the TGIE bit in TIER is
set to 1 when the TGF flag in TSR is set to 1 by the occurrence of a TGR input capture/compare
match on a particular channel. The interrupt request is cleared by clearing the TGF flag to 0. The
TPU has 16 input capture/compare match interrupts, four each for channels 0 and 3, and two each
for channels 1, 2, 4, and 5.
Overflow Interrupt: An interrupt is requested if the TCIEV bit in TIER is set to 1 when the
TCFV flag in TSR is set to 1 by the occurrence of TCNT overflow on a channel. The interrupt
request is cleared by clearing the TCFV flag to 0. The TPU has six overflow interrupts, one for
each channel.
Underflow Interrupt: An interrupt is requested if the TCIEU bit in TIER is set to 1 when the
TCFU flag in TSR is set to 1 by the occurrence of TCNT underflow on a channel. The interrupt
request is cleared by clearing the TCFU flag to 0. The TPU has four underflow interrupts, one
each for channels 1, 2, 4, and 5.
10.5.2 DTC Activation
Note: The DTC is not implemented in the H8S/2635 and H8S/2634.
DTC Activation: The DTC can be activated by the TGR input capture/compare match interrupt
for a channel. For details, see section 8, Data Transfer Controller (DTC).
A total of 16 TPU input capture/compare match interrupts can be used as DTC activation sources,
four each for channels 0 and 3, and two each for channels 1, 2, 4, and 5.
10.5.3 A/D Converter Activation
The A/D converter can be activated by the TGRA input capture/compare match for a channel.
If the TTGE bit in TIER is set to 1 when the TGFA flag in TSR is set to 1 by the occurrence of a
TGRA input capture/compare match on a particular channel, a request to start A/D conversion is
sent to the A/D converter. If the TPU conversion start trigger has been selected on the A/D
converter side at this time, A/D conversion is started.
In the TPU, a total of six TGRA input capture/compare match interrupts can be used as A/D
converter conversion start sources, one for each channel.
REJ09B0103-0800 Rev. 8.00
May 28, 2010
Page 379 of 1458