English
Language : 

SH7280 Datasheet, PDF (697/1726 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperHTM RISC engine family
Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
(16) Operation when Error Occurs during PWM Mode 2 Operation, and Operation is
Restarted in Phase Counting Mode
Figure 11.152 shows an explanatory diagram of the case where an error occurs in PWM mode 2
and operation is restarted in phase counting mode after re-setting.
MTU2 module output
TIOC*A
1
2
3
4
5
RESET TMDR TIOR PFC TSTR
(PWM2) (1 init (MTU2) (1)
0 out)
6
Match
7
8
9
Error PFC TSTR
occurs (PORT) (0)
10
TMDR
(PCM)
11 12 13
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
Not initialized (cycle register)
TIOC*B
Port output
PEn
High-Z
PEn
High-Z
n = 0 to 15
Figure 11.152 Error Occurrence in PWM Mode 2, Recovery in Phase Counting Mode
1 to 9 are the same as in figure 11.149.
10. Set phase counting mode.
11. Initialize the pins with TIOR.
12. Set MTU2 output with the PFC.
13. Operation is restarted by TSTR.
Rev. 1.00 Jun. 26, 2008 Page 667 of 1692