English
Language : 

SH7280 Datasheet, PDF (693/1726 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperHTM RISC engine family
Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
(12) Operation when Error Occurs during PWM Mode 1 Operation, and Operation is
Restarted in Reset-Synchronized PWM Mode
Figure 11.148 shows an explanatory diagram of the case where an error occurs in PWM mode 1
and operation is restarted in reset-synchronized PWM mode after re-setting.
MTU2 module output
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19
RESET TMDR TOER TIOR PFC TSTR Match Error PFC TSTR TMDR TIOR TIOR TOER TOCR TMDR TOER PFC TSTR
(PWM1) (1) (1 init (MTU2) (1)
occurs (PORT) (0) (normal) (0 init(disabled) (0)
(RPWM) (1) (MTU2) (1)
0 out)
0 out)
TIOC3A
TIOC3B
Not initialized (TIOC3B)
TIOC3D
Not initialized (TIOC3D)
Port output
PE8
High-Z
PE9
High-Z
PE11
High-Z
Figure 11.148 Error Occurrence in PWM Mode 1,
Recovery in Reset-Synchronized PWM Mode
1 to 14 are the same as in figure 11.147.
15. Select the reset-synchronized PWM output level and cyclic output enabling/disabling with
TOCR.
16. Set reset-synchronized PWM.
17. Enable channel 3 and 4 output with TOER.
18. Set MTU2 output with the PFC.
19. Operation is restarted by TSTR.
Rev. 1.00 Jun. 26, 2008 Page 663 of 1692
REJ09B0393-0100