Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
of the DMAC transfer may be generated even if the activation sources are cleared. Also, when
transferring DMAC burst by MTU2, the setting of bus function extension register (BSCEHR) is
required. See section 9.4.8, Bus Function Extending Register (BSCEHR), for details.
11.5.3 A/D Converter Activation
The A/D converter can be activated by one of the following three methods in the MTU2. Table
11.58 shows the relationship between interrupt sources and A/D converter start request signals.
(1) A/D Converter Activation by TGRA Input Capture/Compare Match or at TCNT_4
Trough in Complementary PWM Mode
The A/D converter can be activated by the occurrence of a TGRA input capture/compare match in
each channel. In addition, if complementary PWM operation is performed while the TTGE2 bit in
TIER_4 is set to 1, the A/D converter can be activated at the trough of TCNT_4 count (TCNT_4 =
H'0000).
A/D converter start request signal TRGAN is issued to the A/D converter under either one of the
following conditions.
• When the TGFA flag in TSR is set to 1 by the occurrence of a TGRA input capture/compare
match on a particular channel while the TTGE bit in TIER is set to 1
• When the TCNT_4 count reaches the trough (TCNT_4 = H'0000) during complementary
PWM operation while the TTGE2 bit in TIER_4 is set to 1
When either condition is satisfied, if A/D converter start signal TRGAN from the MTU2 is
selected as the trigger in the A/D converter, A/D conversion will start.
(2) A/D Converter Activation by Compare Match between TCNT_0 and TGRE_0
The A/D converter can be activated by generating A/D converter start request signal TRG0N
when a compare match occurs between TCNT_0 and TGRE_0 in channel 0.
When the TGFE flag in TSR2_0 is set to 1 by the occurrence of a compare match between
TCNT_0 and TGRE_0 in channel 0 while the TTGE2 bit in TIER2_0 is set to 1, A/D converter
start request TGR0N is issued to the A/D converter. If A/D converter start signal TGR0N from the
MTU2 is selected as the trigger in the A/D converter, A/D conversion will start.