Section 29 User Debugging Interface (H-UDI)
29.5 Usage Notes
1. An H-UDI command, once set, will not be modified as long as another command is not set
again from the H-UDI. If the same command is to be set continuously, the command must be
set after a command (BYPASS mode, etc.) that does not affect chip operations is once set.
2. In software standby mode, this LSI stops operation and does not accept any H-UDI command.
To retain the TAP status before and after software standby mode, keep TCK high before
entering software standby mode.