English
Language : 

SH7065 Datasheet, PDF (548/941 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH RISC engine Family/SH7000 Series
Section 14 Serial Communication Interface (SCI)
Bit 4—Parity Mode (O/E)/IrDA Clock Select 1 (ICK1): Selects either even or odd parity for use
in parity addition and checking. The O/E bit setting is only valid when the PE bit is set to 1,
enabling parity bit addition and checking, in asynchronous mode. The O/E bit setting is invalid in
synchronous mode, and when parity addition and checking is disabled in asynchronous mode.
Bit 4: O/E
Description
0
Even parity*1
(Initial value)
1
Odd parity*2
Notes: 1. When even parity is set, parity bit addition is performed in transmission so that the total
number of 1-bits in the transmit character plus the parity bit is even. In reception, a
check is performed to see if the total number of 1-bits in the receive character plus the
parity bit is even.
2. When odd parity is set, parity bit addition is performed in transmission so that the total
number of 1-bits in the transmit character plus the parity bit is odd. In reception, a check
is performed to see if the total number of 1-bits in the receive character plus the parity
bit is odd.
In IrDA communication mode, bit 4 is the IrDA clock select 1 (ICK1) bit, enabling appropriate
clock pulses to be generated according to its setting. See, Pulse Width Selection, in section 14.3.6,
Operation in IrDA Mode, for details.
Bit 3—Stop Bit Length (STOP)/IrDA Clock Select 0 (ICK0): Selects 1 or 2 bits as the stop bit
length in asynchronous mode. The STOP bit setting is only valid in asynchronous mode. If
synchronous mode is set, the STOP bit setting is invalid since stop bits are not added.
Bit 3: STOP
Description
0
1 stop bit*1
(Initial value)
1
2 stop bits*2
Notes: 1. In transmission, a single 1-bit (stop bit) is added to the end of a transmit character
before it is sent.
2. In transmission, two 1-bits (stop bits) are added to the end of a transmit character
before it is sent.
In reception, only the first stop bit is checked, regardless of the STOP bit setting. If the second
stop bit is 1, it is treated as a stop bit; if it is 0, it is treated as the start bit of the next transmit
character.
In IrDA communication mode, bit 3 is the IrDA clock select 0 (ICK0) bit, enabling appropriate
clock pulses to be generated according to its setting. See, Pulse Width Selection, in section 14.3.6,
Operation in IrDA Mode, for details.
Rev. 5.00 Sep 11, 2006 page 526 of 916
REJ09B0332-0500