22. Remote Control Signal Receiver
Table 22.19 Registers and Setting Values in Input Capture Mode (Simultaneous Count Operation)
(1/2)
Register
PMCiCON0
Bit
EN
PMCiCON1
PMCiCON2
SINV
FIL
EHOLD
HDEN
SDEN
DRINT0
DRINT1
TYP0
TYP1
CSS
EXSDEN
EXHDEN
ENFLG
INFLG
CEFLG
CEINT
PSEL0
PSEL1
PMCiCON3 CRE
CFR
CST
PD
CSRC0
CSRC1
CDIV0
CDIV1
PMCiSTS
CPFLG
REFLG
DRFLG
BFULFLG
PTHDFLG
PTD0FLG
PTD1FLG
SDFLG
i = 0, 1
-: No register bit in PMC1
PMC0
1. (Refer to 22.3.5.1 “Setting
Procedure”)
Select input signal polarity
Select filter enabled/disabled
0
0
0
00b
Function
PMC1
1. (Refer to 22.3.5.1 “Setting
Procedure”)
Select input signal polarity
Select filter enabled/disabled
-
0
-
-
Select measuring object
Select measuring object
1
0
0
Flag indicating PMCi operated/
stopped
Input signal flag
Counter overflow flag
Set to 1 when using counter
overflow interrupt
01b
-
-
-
Flag indicating PMCi operated/
stopped
Input signal flag
Counter overflow flag
Set to 1 when using counter
overflow interrupt
10b
1
1
1
1
1
1
1
1
00b
Select clock source
00b
Select count source divisor
Not used (read as undefined value) -
Not used (read as undefined value) Not used (read as undefined value)
Not used (read as undefined value) Not used (read as undefined value)
Not used (read as undefined value) -
Not used (read as undefined value) Not used (read as undefined value)
Not used (read as undefined value) Not used (read as undefined value)
Not used (read as undefined value) Not used (read as undefined value)
Not used (read as undefined value) -
REJ09B0484-0030 Rev.0.30 Sep 09, 2008